SONOFF Zigbee датчик Температуры и влажности
Дополнительные действия
приложение:eWeLink
Расчетное время жизни - 51.2 месяца
Structure Endpoint 1 (TEMPERATURE_SENSOR) Input 0000_Basic 0000_ZCLVersion: 8 [UNSIGNED_8_BIT_INTEGER] 0001_ApplicationVersion: 0 [UNSIGNED_8_BIT_INTEGER] 0003_HWVersion: 0 [UNSIGNED_8_BIT_INTEGER] 0004_ManufacturerName: eWeLink [CHARACTER_STRING] 0005_ModelIdentifier: SNZB-02P [CHARACTER_STRING] 0006_DateCode: 20230821 [CHARACTER_STRING] 0007_PowerSource: 3 [ENUMERATION_8_BIT] 4000_SWBuildID: 2.1.0 [CHARACTER_STRING] 0020_PollControl 0001_PowerConfiguration 0021_BatteryPercentageRemaining: 200 [UNSIGNED_8_BIT_INTEGER] FC11_ManufacturerSpecific 0402_TemperatureMeasurement 0000_MeasuredValue: 2560 [SIGNED_16_BIT_INTEGER] 0003_Identify 0405_RelativeHumidityMeasurement 0000_MeasuredValue: 4760 [UNSIGNED_16_BIT_INTEGER] FC57_ManufacturerSpecific Output 0003_Identify 0019_OtaUpgrade
Binding table
Endpoint Mode Address Cluster
1 IEEE [3] Sprut zigbee Новая комната (1) 0402_TemperatureMeasurement
1 IEEE [3] Sprut zigbee Новая комната (1) 0405_RelativeHumidityMeasurement
1 IEEE [3] Sprut zigbee Новая комната (1) 0001_PowerConfiguration
Group membership
Associated devices
Neighbor table
Routing table
Node Descriptor Aps Flags 0 Frequency Bands [FREQ_2400_MHZ] Server Capabilities [] Buffer Size 82 Incoming Transfer Size 255 Logical Type End Device Mac Capabilities [REDUCED_FUNCTION_DEVICE] Manufacturer Code 0x1286 (4742) Out Going Transfer Size 255 Stack Compliance 22
Power Descriptor Current Power Mode RECEIVER_ON_IDLE Available Power Sources [MAINS] Current Power Source MAINS Power Level FULL
OTA info Image type 0x0807 (2055) File version 0x00002100 (8448) 0_0_33_0 Manufacturer code 0x1286 (4742)
Mode: ZCL Last update: Thu Aug 06 16:10:56 MSK 2026
Address: 7CC6B6FFFE0BAAE3/B50D
Structure Endpoint 1 (TEMPERATURE_SENSOR) Input 0000_Basic 0000_ZCLVersion: 8 [UNSIGNED_8_BIT_INTEGER] 0001_ApplicationVersion: 0 [UNSIGNED_8_BIT_INTEGER] 0003_HWVersion: 0 [UNSIGNED_8_BIT_INTEGER] 0004_ManufacturerName: eWeLink [CHARACTER_STRING] 0005_ModelIdentifier: SNZB-02P [CHARACTER_STRING] 0006_DateCode: 20230821 [CHARACTER_STRING] 0007_PowerSource: 3 [ENUMERATION_8_BIT] 4000_SWBuildID: 2.1.0 [CHARACTER_STRING] 0020_PollControl 0001_PowerConfiguration 0021_BatteryPercentageRemaining: 200 [UNSIGNED_8_BIT_INTEGER] FC11_ManufacturerSpecific 0402_TemperatureMeasurement 0000_MeasuredValue: 2560 [SIGNED_16_BIT_INTEGER] 0003_Identify 0405_RelativeHumidityMeasurement 0000_MeasuredValue: 4760 [UNSIGNED_16_BIT_INTEGER] FC57_ManufacturerSpecific Output 0003_Identify 0019_OtaUpgrade
Binding table
Endpoint Mode Address Cluster
1 IEEE [3] Sprut zigbee Новая комната (1) 0402_TemperatureMeasurement
1 IEEE [3] Sprut zigbee Новая комната (1) 0405_RelativeHumidityMeasurement
1 IEEE [3] Sprut zigbee Новая комната (1) 0001_PowerConfiguration
Group membership
Associated devices
Neighbor table
Routing table
Node Descriptor Aps Flags 0 Frequency Bands [FREQ_2400_MHZ] Server Capabilities [] Buffer Size 82 Incoming Transfer Size 255 Logical Type End Device Mac Capabilities [REDUCED_FUNCTION_DEVICE] Manufacturer Code 0x1286 (4742) Out Going Transfer Size 255 Stack Compliance 22
Power Descriptor Current Power Mode RECEIVER_ON_IDLE Available Power Sources [MAINS] Current Power Source MAINS Power Level FULL
OTA info Image type 0x0807 (2055) File version 0x00002100 (8448) 0_0_33_0 Manufacturer code 0x1286 (4742)
Mode: ZCL
Last update: Thu Aug 06 16:10:56 MSK 2026Результаты тестирования
Оценки приводятся по шкале от 1 до 10:
| Шаг | Описание действия/процедуры | Оценка | Комментарии |
|---|---|---|---|
| 1 | Комплектация изделия на соответствие заявленному комплекту поставки. | 10 | |
| 2 | Общий вид изделия, качество сборки, качество материалов | 10 | |
| 3 | Соответствие размеров устройства паспортным данным | 10 | По паспорту: 45x45x17.7 мм По факту: 44,93*44,93*17.79мм |
| 4 | Геометрия устройства (ровность граней, ребер и т.д) | 10 | |
| 5 | Соответствие и количество заявленных интерфейсов паспортным значениям | 10 | |
| 6 | Качество изготовления и монтажа электронных компонентов | 10 |
Функциональное тестирование
| Шаг | Описание действия/процедуры | Оценка | Комментарии |
|---|---|---|---|
| 1 | Простота первоначальной настройки устройства | 10 | |
| 2 | Работа в сценариях через хаб | 10 | |
| 3 | Стабильность подключения устройства к сети | 10 | |
| 4 | Корректность работы индикации | 10 | |
| 5 | Соответствие функционалов родного приложения и Sprut'a | 10 | |
| 6 | Сравнение показаний термометра в 3 точках с эталоном | 9 | |
| 7 | Сравнение показаний гигрометра в 3 точках с эталоном | 8 | |
| 8 | Сравнение показаний люксометра в 3 точках с эталоном | - | |
| 9 | Наличие калибровки по температуре и по влажности. | 10 | Есть калибровка |
| 10 | Удобство считывания показаний с экрана расстояния 2 метра.(размер физического шрифта) | - | Нет экрана |
Заключение
Хороший результат по точности измерения температуры, выше среднего по влажности, хорошая автономность, доступная цена.